Input Options |
TurboWedge 1 |
Input Port 1
| Bar Code Wands, Lasers, CCD's, Bar Code Slots, etc. |
|
Input Port 2
| Magnetic Stripe- Single/Dual Track
Serial RS 232 - Portable Terminals, Scales, etc. |
TurboWedge 2 |
Input Port 1
| Bar Code
Wands, Lasers, CCD's, Bar Code Slots, etc. |
|
Input Port 2
| Serial RS 232 - Portable Terminals, Scales, etc.
Bar Code Scanners - Wand Emulation |
| Input Port 3 |
Magnetic Stripe -
Single/Dual or Triple Track |
Interface Options
- Keyboard Wedge
- Serial RS 232 - Single Port
- Serial RS 232 - In-Line (Dual Port)
Compsee's 5th generation keyboard wedge. For all around price
and performance the versatility of the TurboWedge provides the user
with a multitude of features and functions. Using state-of-the-art
powerful and flexible Flash EPROM technology has allowed Compsee
to develop a small footprint wedge that combines all the features
of previous Compsee wedges with numerous new user-friendly program
parameters.
The TurboWedge excels when it comes to input and output options.
Input devices supported include bar code reader, Magnetic Stripe
Readers and RS 232 input devices such as scales and portable terminals.
Data passing through the TurboWedge can be decoded, edited and transmitted
either as keyboard input or RS 232 ASCII. Wedge interface connections
supported include all types of PC's and clones, as well a variety
of other terminals from DEC, IBM, HP, Wyse, etc.
Installation of the wedge is simple and fast, simply plug between
the keyboard and the terminal. For customization, the user can choose
from seven different methods to program the TurboWedge set up parameters.
Added to the traditional menu and cloning methods is serial or bar
code batch, symbology validation, on-screen or Compsee's Windows
based PC program WinCape.
As with all Compsee wedges, the TurboWedge contains the powerful
editing features that allow the user to qualify the data input,
inhibit invalid data from passing through and then format the output
of the data to match the applications input screen
Specifications
Interface Options
RS 232 - Single or Dual (In-Line) Port
Keyboard Wedge - Call for additional Interface Options |
Apple |
MACINTOSH |
AT&T; |
6500 |
IBM |
PC XT/AT, PS/2, 3151, 3161, 3163,
3179-1, 3179-2, 3180-1,
3180-2, 3191, 3192, 3196, 3197,
3471, 3472, 3476, 3478, 3477, 3481,
3486, 3487 |
DEC |
220, 320, 420 |
Decision Data |
3776, 3496, 3497, 3596-122K,
3596-83K, 3596-102K
3781, 3776, 386, 387C |
Hewlett Packard |
700-43/60/92/96, 2392-A,
HIL, Vectra |
Memorex |
1196, 1475, 2192 |
Telex |
191, 78X, 79X, 80X, 1192,1196, 1476, 1197 |
Wyse |
30
ASCII Keyboard
ANSI 105 Keyboard
PC Enhanced 102 Keyboard
ANSI Enhanced 108 Keyboard |
Bar Code Symbologies
Auto-discriminates between the following symbologies |
Code 3 of 9 |
Extended Code 3 of 9 |
UPC A |
Interleaved 2 of 5 |
Industrial 2 of 5 |
UPC E |
Codabar |
Code 11 |
EAN/JAN 8 |
Code 128 |
Plessey |
EAN/JAN 13 |
Code 93 |
Matrix 2 of 5 |
|
Input Options
Bar Code Readers |
|
- Non-Contact |
Lasers CCD's Presentation (Slot) Scanners |
|
- Contact |
Wands Bar Code Slot |
Magnetic Stripe Readers |
|
Single Track |
1, 2 or 3 |
|
Dual Track |
1 & 2, 1 & 3 or 2 & 3 |
|
Triple Track |
1, 2 & 3 (TurboWedge 2 Only) |
RS 232 Auxiliary Input |
|
Portable Terminals Scales Slot Scanners |
|
Dimensions
|
Length |
3.65" |
|
Height |
1.10" |
|
Width |
3.75" |
|
Weight |
3.5 oz. |
Power Requirements
Power is consumed from the terminal on most
keyboard interfaces. An external 9 Volt power supply
is required for some terminal interfaces and for RS 232
communications.
Environmental Characteristics
|
Operating Temperature |
+32° F to +122° F
(-5° C to +40° C) |
|
NonOperating Temperature |
-77° F to +140° F
(-20° C to +65° C) |
|
Relative Humidity |
To 95% (NonCondensing) |
|
Electrostatic Discharge |
15KV to any external surface |
|
EMC Regulations |
FCC and CE |
Keyboard Wedge Programming
The TurboWedge programmability lets the user customize
by defining data input validation and data output formatting
Program Modes
|
Default All |
Reset to Factory Defaults |
|
Bar Code Menu |
Program by scanning individual bar codes
for menu selection |
|
Bar Code Batch |
Combine multiple program selections into
one bar code for program scanning |
|
Serial Batch |
Program selections are communicated
to the unit via the RS 232 Port |
|
On-Screen |
For PC's only. Menus are displayed
on the screen and selections
made and transmitted via the
keyboard with the unit attached
as a keyboard wedge |
|
WinCape |
PC Based Program |
|
Wedge Clone |
Copy the program from one wedge
to another |
|
Symbology Validation |
Program the unit to read only
specific bar code types and lengths |
General Parameters
|
Terminal Type |
Keyboard Type |
|
Numeric Keypad |
Intercharacter Delay |
|
Beeper Volume |
Interfunction Delay |
|
Mag Track Selection |
Set Pause Time |
|
Scale Solicit Record |
Laser with Marker Beam |
|
Output Edited Records Only |
Turbo Mode Wyse/HP |
|
Laser with Auto Sense |
Turbo Mode Wyse/HP |
Bar Code Input Parameters
|
Preamble - (Up to 16 Characters or Functions) |
|
Postamble - (Up to 16 Characters or Functions) |
|
Embedded Function Code |
Code Identification |
|
AutoScan |
MultiScan |
|
Redundancy |
Code ID Transmit |
|
Code Enable/Disable |
Code Length |
|
Check Digit Checks |
Start/Stop Transmit |
|
Check Digit Transmit |
|
Serial Parameters
|
Baud Rate |
Parity |
|
Word Length |
Stop Bits |
|
Input RS232 Protocol |
Dual Port Protocol |
|
Record Terminator |
Fixed Length Enable |
|
Transmit Path |
Embedded Function Codes |
Input/Output Data Edit Parameters
|
Qualify by Port |
Add Data |
|
Qualify by Symbology |
Delete Data |
|
Qualify by Length |
Reformat Data |
|
Qualify by Data Match |
Define 2 Output Formats |
Keyboard Mapping Parameters
|
Single Key Positions |
Data Records |
|
Multiple Key Positions |
Function Records |
Examples - User Programming
|
1) Qualify by Length,
Symbology and 2 Match Positions
|
|
- If Code 3 of 9 |
- Position 4 = M |
|
- 12 Digits |
- Position 7 = T |
|
Output Format = |
Ignore Match Characters,
Insert Tab and Enter |
|
Input Record = |
192M74T93842 |
|
Output Format = |
192<Tab>7493842<Enter> |
|
2) Qualify by Symbology and 1 Match Position
|
|
- If Code 128 |
- Position 8 = 5 |
|
- Variable Length |
|
|
Output Format = |
Ignore Match Character, Insert Data and Function Codes |
|
Input Record = |
00433005920000223 |
|
Output Format = |
0043300<F9><9001><Enter>
920000223<ALT"B"> |
|
|