  • Input Options
    TurboWedge 1 Input Port 1 Bar Code
    Wands, Lasers, CCD's, Bar Code Slots, etc.
      Input Port 2 Magnetic Stripe- Single/Dual Track
    Serial RS 232 - Portable Terminals, Scales, etc.

    TurboWedge 2 Input Port 1 Bar Code
    Wands, Lasers, CCD's, Bar Code Slots, etc.
      Input Port 2 Serial RS 232 - Portable Terminals, Scales, etc.
    Bar code scanners - Wand Emulation
      Input Port 3 Magnetic Stripe
    Single/Dual or Triple Track

    Interface Options

  • Keyboard Wedge
  • Serial RS 232 - Single Port
  • Serial RS 232 - In-Line (Dual Port)

    Compsee�s 5th generation keyboard wedge. For all around price and performance the versatility of the TurboWedge provides the user with a multitude of features and functions. Using state-of-the-art powerful and flexible Flash EPROM technology has allowed Compsee to develop a small footprint wedge that combines all the features of previous Compsee wedges with numerous new user-friendly program parameters.

    The TurboWedge excels when it comes to input and output options. Input devices supported include bar code reader, Magnetic Stripe Readers and RS 232 input devices such as scales and portable terminals. Data passing through the TurboWedge can be decoded, edited and transmitted either as keyboard input or RS 232 ASCII. Wedge interface connections supported include all types of PC�s and clones, as well a variety of other terminals from DEC, IBM, HP, Wyse, etc.

    Installation of the wedge is simple and fast, simply plug between the keyboard and the terminal. For customization, the user can choose from seven different methods to program the TurboWedge set up parameters. Added to the traditional menu and cloning methods is serial or bar code batch, symbology validation, on-screen or Compsee�s Windows based PC program WinCape.

    As with all Compsee wedges, the TurboWedge contains the powerful editing features that allow the user to qualify the data input, inhibit invalid data from passing through and then format the output of the data to match the applications input screen

    Specifications

    Interface Options
    RS 232 - Single or Dual (In-Line) Port
    Keyboard Wedge - Call for additional  Interface Options
    
      APPLE MACINTOSH AT&T 6500 IBM PC XT/AT, PS/2, 3151, 3161, 3163 3179�1, 3179�2, 3180�1, 3180�2, 3191, 3192, 3196, 3197, 3471, 3472, 3476, 3478, 3477, 3481, 3486, 3487 DEC 220, 320, 420 DECISION DATA 3776, 3496, 3497, 3596�122K 3596�83K, 3596-102K 3781, 3776, 386, 387C HEWLETT PACKARD 700-43/60/92/96, 2392-A, HIL, Vectra MEMOREX 1196, 1475, 2192 TELEX 191, 78X, 79X, 80X, 1192 1196, 1476, 1197 WYSE 30 ASCII Keyboard ANSI 105 Keyboard PC Enhanced 102 Keyboard ANSI Enhanced 108 Keyboard
    Bar Code Symbologies
      Auto-discriminates between the following symbologies Code 3 of 9 Code 3 of 9 Extended Interleaved 2 of 5 Industrial 2 of 5 Codabar Code 11 Code 128 Plessey Code 93 Matrix 2 of 5 UPC A EAN/JAN 8 UPC E EAN/JAN 13
    Input Options
      Bar Code Readers - Non-Contact Lasers CCD's Presentation (Slot) Scanners - Contact Wands Bar Code Slot Magnetic Stripe Readers Single Track 1, 2 or 3 Dual Tracks 1 & 2, 1 & 3 or 2 & 3 Triple Tracks 1, 2 & 3 (TurboWedge 2 Only) RS 232 Auxiliary Input Portable Terminals Scales Slot Scanners
    Dimensions
      Length 3.65" Height 1.10" Width 3.75" Weight 3.5 oz.
    Power Requirements
      Power is consumed from the terminal on most keyboard interfaces. An external 9 Volt power supply is required for some terminal interfaces and for RS 232 communications.
    Environmental Characteristics
      Operating Temperature +32° F to +122° F -5° C to +40° C Non­Operating Temperature -77° F to +140° F -20° C to +65° C Relative Humidity To 95% (Non­Condensing) Electrostatic Discharge 15KV to any external surface EMC Regulations FCC and CE


    The TurboWedge programmability lets the user customize by defining data input validation and data output formatting
    Program Modes
      Default All Reset to Factory Defaults Bar Code Menu Program by scanning individual bar codes for menu selection Bar Code Batch Combine multiple program selections into one bar code for program scanning. Serial Batch Program selections are communicated to the unit via the RS 232 Port. On-Screen For PC's only. Menus are displayed on the screen and selections made and transmitted via the keyboard with the unit attached as a keyboard wedge. WinCape PC Based Program Wedge Clone Copy the program from one wedge to another. Symbology Validation Program the unit to read only specific bar code types and lengths.


    Download WinCape
    TurboWedge Configuration Program

    (1.8 Mb)

    General Parameters
      Terminal Type Keyboard Type Foreign Keyboard Numeric Keypad Buffer Enable/Disable Beeper Volume Intercharacter Delay Mag Track Select Interfunction Delay Scale Solicit Record Set Pause Time Output Edited Records Only Laser with Marker Beam Laser with Auto Sense Turbo Mode - Wyse/HP
    Bar Code Input Parameters
      Preamble - (Up to 16 Characters or Functions) Postamble - (Up to 16 Characters or Functions) Embedded Function Code Code Identification AutoScan MultiScan Redundancy Code ID Transmit Code Enable/Disable Code Length Check Digit Checks Start/Stop Transmit Check Digit Transmit
    Serial Parameters
      Baud Rate Parity Word Length Stop Bits Input RS232 Protocol Dual Port Protocol Record Terminator Fixed Length Enable Transmit Path Embedded Function Codes
    Input/Output Data Edit Parameters
      Qualify by Port Add Data Qualify by Symbology Delete Data Qualify by Length Reformat Data Qualify by Data Match Define 2 Output Formats
    Keyboard Mapping Parameters
      Single Key Positions Data Records Multiple Key Positions Function Records
    Examples - User Programming
      1) Qualify by Length, Symbology and 2 Match Positions - If Code 3 of 9 - Position 4 = M - 12 Digits - Position 7 = T Output Format = Ignore Match Characters, Insert Tab and Enter Input Record: 192M74T93842 Output Format: 192<Tab>7493842<Enter> 2) Qualify by Symbology and 1 Match Position - If Code 128 - Position 8 = 5 - Variable Length Output Format = Ignore Match Character Insert Data and Function Codes Input Record: 00433005920000223 Output Format: 0043300<F9><9001><Enter> 920000223<ALT"B">