CERTIFICATE
OF CONFORMANCE / CALIBRATION
PRODUCT: |
QUICK CHECK® Bar Code Verifier |
MODEL: |
QCSample |
SERIAL NUMBER(S): |
01234 |
CERTIFICATION DATE: |
98/01/01 |
RE-CERTIFICATION DATE(s): |
99/01/01 |
The above mentioned QUICK CHECK® Bar Code Verifier has been
manufactured, calibrated and tested to conform with the specifications
found in the following standards:
-
Primary:
- ISO/IEC 15426 Bar code verifier conformance specification
- Part 1 Linear
- ISO/IEC 15416 Bar code print quality test specification
- Secondary:
- CEN ENV12647 Bar coding - Test specifications for bar code
verifiers
- CEN EN1635 Bar coding - Test specifications - Bar code symbols
- ANSI X3.182 Guideline for Bar Code Print Quality
As part of this process calibration standards produced by Applied
Image and traceable to the National Institute for Standards and
Technology (NIST) have been used.
Initial optical and reflectance calibration is performed at the
time of manufacture of this instrument. As with all precision
electro-optical reflectance measuring devices, periodic re-calibration
may be necessary. Reflectance re-calibration is only necessary
when the device has had a new wand scanner installed, the batteries
have been removed/exchanged, the unit detects during its auto-test
at start up that the scanner has degraded or the unit has lost
part of it's calibration information which is stored in non-volatile
memory. In each of these cases the unit can be re-calibrated by
the user and will prompt the user to recalibrate (using the supplied
QCRF - Reflectance Calibration Patch or QCRFPG - Reflectance Calibration
Page).
Note that the user can set more stringent or frequent reflectance
re-calibration requirements to suit their internal quality control
procedures and philosophy. As a suggestion, if the unit is used
daily (eight hours per day), daily re-calibration would be recommended.
If used only a few times a week, re-calibration at the time of
the use would not be detrimental. Re-calibration takes less than
60 seconds.
Full re-certification of the verifier can be performed by contacting
PSC's Service organization at Tel: #716-265-1600 (#800-828-6489)
or your nearest PSC Dealer or Subsidiary. PSC recommends full
re-certification annually or as required by your internal quality
and conformance procedures.
Additional information on standards conformance, traceability,
performance and calibration references follows:
ISO/IEC Reflectance and Dimensional Measurement Parameters
Quick Check® Verifiers meet or exceed all of the conformance
criteria found in International standard ISO/IEC 15426 Bar code
verifier conformance specification - Part 1 Linear, when used
for measuring and reporting the bar code quality criteria found
in International standard ISO/IEC 15416 Bar code print quality
test specification following the manufacturer's recommendations
for use and operation.
Additionally, controlled tests have found the following to be
reliable reflectance variability values:
Accuracy: |
(Rmax) ± 5.0% (to a known sample) |
|
(Rmin) ± 3.0% (to a known sample) |
Repeatability: |
± 3.0% (within one unit, tested on a known sample) |
Traditional Average Bar / Space Measurements
The QUICK CHECK® detects errors in bar code printing (uniform
bar growth or shrinkage) to a precision of +/- 3.0% of the nominal
narrow bar size or +/- 0.0005", whichever is greater.
Calibration / Standards Measurement
For conformance and traceability purposes Quick Check® Bar
Code Verifiers are designed, set up and tested using the following
calibrated standard test pieces.
-
PSC Part # 5821 - QCRF - Reflectance Calibration
Patch
-
PSC Part # 50600 - QCRFPG - Reflectance Calibration
Page
-
PSC Part # 11405 - PSC QUICK CHECK® Optics
Qualification Test Symbol
-
Applied U.P.C. Primary Verification Calibration
Standards
-
Applied Calibrated Conformance Standard Test
Card For EAN/UPC Symbol Verifiers
-
Applied U.P.C. Secondary Verification Calibration
Standards
-
Applied Code 39 & Code 128 Verification
Calibration Standards
Calibration and traceability certificates are available for the
PSC QCRF and QCRFPG supplied with your verifier by contacting
PSC Customer Administration or your nearest PSC Dealer or Subsidiary.
All of the above test items are manufactured by Applied Image
Inc. (1653 East Main Street, Rochester NY 14609 TEL: 716-482-0300,
FAX: 716-288-5989) and are manufactured and inspected on equipment
calibrated with techniques, processes and standards traceable
to the National Institute of Standards and Technology U.S.A.
Format Testing
Quick Check® Verifiers conform to numerous industry application
standards for format testing and limit set points as outlined
in standards created for the following Automatic Identification
and Data Collection industry segments:
-
Automotive
-
Retail
-
Transportation / Logistics
-
Manufacturing / Industrial
-
Healthcare / Pharmaceutical
-
Publishing
-
Governmental
In providing this application specific format testing specifications
have been used in part or in total in the development of the Quick
Check® Verifier Product Line that have been published by the
following organizations and / or agencies:
AIM, Inc.
634 Alpha Drive
Pittsburgh, PA 15238-2802
|
EAN International
Rue Royale 29
B-1000 Bruxelles
Belgium |
American Blood Commission
700 North Fairfax Street, Suite 505
Alexandria, VA 22314 |
Health Industry Business Communications Council
(HIBCC)
5110 N. 40th Street, Suite 120
Phoenix, AZ 85018 |
American National Standards Institute
11 West 42nd St., 13th Floor
New York, NY 10036 |
International Council for Commonality in Blood
Banking Automation, Inc.
4737 University Drive
3 University Place
Durham, NC 27707 |
Automotive Industry Action Group (AIAG)
26200 Lahser Road, Suite 200
Southfield, MI 48034 |
International Standard Book Numbering (ISBN)
U.S.Agency, 245 West 17th St
New York, NY 10011 |
Book Industry Study Group, Inc.
160 Fifth Avenue
New York, NY 10010 |
International Standard Serial Number (ISSN)
Library of Congress
Washington, DC 20540 |
Commission for European Normalization
36 Rue de Stassart
B-1050 Bruxelles Belgium |
Uniform Code Council
7887 Washington Village Drive
Suite 300
Dayton, OH 45459 |
Department of Defense (LOGMARS)
Director, AMPCSCC, Attn: SDSTO-TA
Tobyhanna, PA 18466-5097 |
|
Charles E. Biss
Vice President, Verification Products
CERTIFICATE OF CONFORMANCE / CALIBRATION
PRODUCT: |
QUICK CHECK® Bar Code Verifier
Reflectance Standard |
MODEL: |
QCSample |
SERIAL NUMBER(S): |
B01234 |
CERTIFICATION DATE: |
84.1% |
The above mentioned QUICK CHECK® Bar Code Verifier accessory
has been manufactured, calibrated and tested by a National Institute
for Standards and Technology (NIST) certified laboratory (Applied
Image, Inc., 1653 East Main Street, Rochester, New York 14609
USA) in conformance with specifications provided by PSC Inc.
Initial calibration was performed at the time of manufacture.
Due to the nature of use and the base material of this item, repeated
use will degrade its quality.
It is recommended the reflection calibration standard page (QCRFPG)
be kept in a clean, dark, moisture free location when not in use
and the reflectance standard (QCRF and QCRFPG) should be replaced
annually. Either standard (QCRF or QCRFPG) should be replaced
as soon as any evidence of surface deterioration is visually detected
or if the Quick Check it is used with fails to accept it for calibration.
Charles E. Biss
Vice President, Verification Products
Click here to return